Transformers can vary enormously in size, voltage, power rating and application, but the fundamental principles behind their construction remain surprisingly similar.
Whether it is a small single-phase transformer used within a control system or a large three-phase industrial transformer, every transformer relies on a combination of magnetic, electrical and mechanical components working together.
Understanding the parts of a transformer helps explain not only how transformers operate, but also why two transformers with apparently similar ratings can have very different physical designs and electrical characteristics.
At R Baker (Electrical) Ltd, we design and manufacture bespoke dry-type transformers from our facility in Liverpool, with designs developed around the individual electrical, mechanical and environmental requirements of each application.
What are the main parts of a transformer?
A typical dry-type transformer consists of several key elements:
The magnetic core, primary winding, secondary winding, insulation system, terminals, mechanical frame or clamping structure and cooling arrangement.
Additional components may then be included depending on the design, such as tapping arrangements, thermal protection, electrostatic screens, additional insulation barriers and protective enclosures.
Each component performs a specific role, but transformer performance depends on how all these elements interact.
Transformer core
At the centre of a transformer is the magnetic core.
The core provides a controlled magnetic path linking the primary and secondary windings. When alternating current flows through the primary winding, it establishes an alternating magnetic flux within the core.
That changing magnetic field then induces a voltage within the secondary winding.
Transformer cores are typically manufactured from laminated electrical steel. Rather than using one solid piece of steel, thin insulated laminations are assembled together.
This construction helps reduce circulating currents within the core, known as eddy currents, and therefore reduces unwanted losses and heating.
Core dimensions and material selection are important elements of transformer design.
Factors including operating voltage, frequency, flux density, losses, temperature rise and inrush current can all influence the final core design.
Primary winding
The primary winding is connected to the incoming electrical supply.
Alternating current passing through this winding creates the magnetic field within the transformer core.
The number of turns within the primary winding is determined by several design parameters, including the applied voltage, operating frequency, core area and selected magnetic flux density.
Primary windings may use copper or aluminium conductors depending on the transformer specification.
Conductor size must also be carefully selected to manage current density, losses and temperature rise
Secondary winding
The secondary winding supplies the required output voltage to the connected equipment.
The relationship between the number of primary and secondary turns determines the approximate voltage transformation ratio.
For example, a transformer designed to reduce 400 V to 110 V will have a different winding relationship to one designed to increase 230 V to 415 V.
Secondary windings must also be designed around the required current.
A lower-voltage secondary will normally carry a higher current for a given kVA rating and may therefore require substantially larger conductors.
Early consideration can also reduce the risk of extensive modifications later in the qualification programme.
Transformer insulation
Insulation is one of the most important elements within any transformer.
The insulation system prevents electrical contact between:
- individual winding turns;
- separate windings;
- windings and the magnetic core;
- conductors and the transformer frame.
Different insulating materials may be used throughout a transformer depending on voltage, temperature and mechanical requirements.
These can include enamelled winding wire, insulation papers, films, pressboard, glass-based materials, varnishes, sleeving and specialist high-temperature insulation systems.
The selected insulation system also contributes towards the transformer’s thermal classification and expected operating life.
Insulating spacers and winding supports
Transformer windings must be mechanically supported.Insulating blocks, spacers and supports are therefore used to maintain electrical clearances while holding the coils securely in position.
These components can become particularly important where a transformer must withstand vibration, shock or high electromagnetic forces during fault conditions.
Mechanical design and electrical design therefore cannot be considered separately.
The winding may be electrically correct, but it must also remain securely supported throughout the transformer’s operating life.
Transformer terminals
The transformer terminals provide the connection between the internal windings and the external electrical system.
Depending on current and voltage, these may be relatively simple studs or terminal blocks, or substantially larger copper bars and connection arrangements.
For higher-current transformers, termination design becomes increasingly important.
The terminal system must have suitable:
- current-carrying capacity;
- electrical clearance;
- creepage distance;
- mechanical strength;
- temperature performance.
Custom transformer designs may also require the terminal positions to suit an existing installation or replacement footprint.
Tapping connections
Some transformers incorporate voltage tapping arrangements.
Tappings allow the effective number of turns within a winding to be altered, enabling adjustment of the transformer ratio.
For example, an incoming supply that varies slightly from its nominal voltage can sometimes be compensated for by selecting a different transformer tap.
Depending on the design, taps may be provided through simple links, terminal connections or a dedicated tap-changing arrangement.
Transformer frame and clamping system
The transformer core and coils must be held together mechanically.
Steel channels, tie rods, clamping plates and other structural components are commonly used to produce a rigid transformer assembly.
The frame performs several functions.
It supports the transformer, maintains the core assembly, controls movement within the windings and provides suitable mounting points for installation.
For industrial, rail, marine and defence transformers, the mechanical construction may be designed specifically around shock and vibration requirements.
Air cooling and ventilation
The illustration above shows an open-style air-cooled transformer, often referred to as a dry-type transformer.
During operation, electrical and magnetic losses generate heat within both the core and the windings.
That heat must be removed to keep the transformer within its permitted temperature limits.
In naturally air-cooled designs, air circulates around and between the windings and core.
Cooling ducts can be incorporated into the transformer construction to improve airflow through the hottest areas.
As warm air rises, cooler surrounding air is drawn into the transformer, creating natural convection.
Larger or more demanding transformers may instead use forced-air cooling.
Earth connection
Exposed conductive metalwork is normally provided with a suitable protective earth connection.
The earth point allows the transformer frame and associated metallic components to be bonded into the installation’s protective earthing system.
Where additional electrostatic screens are used between windings, separate screen earth connections may also be required depending on the transformer design.
Transformer enclosure
Not every transformer is supplied as an open assembly.
A transformer may instead be installed within a protective enclosure.
The enclosure can protect against accidental contact, contamination and environmental conditions while also controlling access to live electrical connections.
Different applications may require different ingress protection ratings.
However, enclosure design must also consider cooling.
Reducing ventilation can increase internal temperatures, so enclosure and transformer thermal design must be considered together.
How transformer components affect performance
Transformer design is essentially a balance between numerous competing requirements.
Increasing the conductor size may reduce winding losses, but increases the physical size and cost of the transformer.
Reducing flux density may reduce core losses and potentially alter inrush characteristics, but normally requires a larger magnetic core.
Increasing insulation clearances improves electrical separation but also increases the overall dimensions of the assembly.
Adding an enclosure improves physical protection but may make natural cooling more difficult.
This is why transformer design cannot simply be reduced to selecting a kVA rating and voltage.
The application determines the design.
Custom transformer design
For many industrial applications, an off-the-shelf transformer may not meet the complete requirement.
Projects can include restrictions involving:
- input and output voltage;
- kVA rating;
- physical dimensions;
- mounting arrangement;
- terminal position;
- inrush current;
- losses;
- temperature rise;
- insulation class;
- environmental conditions;
- shock and vibration;
- ingress protection;
- applicable industry standards.
R Baker designs and manufactures custom single-phase and three-phase transformers in the UK, including equipment for industrial, rail, offshore and defence applications. The company’s published transformer range extends up to 250 kVA. R Baker (Electrical) Ltd
Why understanding transformer construction matters
Looking inside a transformer shows why transformer engineering involves far more than simply winding copper around an iron core.
The electrical characteristics, magnetic circuit, insulation, cooling and mechanical construction all influence one another.
Understanding transformer provides a useful starting point when specifying, maintaining or designing transformer equipment.
And for applications where space, environment or electrical performance impose unusual requirements, those basic components can be engineered in very different ways to produce a transformer specifically suited to the installation.
To learn more about our services click on the links below for our social media feeds.